Foam we spray

Accufoam CC-HFO Closed-Cell Spray Foam

Accufoam CC-HFO, sold by our supplier as Accufoam 2.0# HFO Closed Cell, is our main closed-cell foam. It is what we spray on steel buildings, rim joists, crawl spaces and anywhere water contact is possible. Every number here comes from the manufacturer's data sheet.

In short

Closed-cell, low GWP

A medium-density foam. The data sheet describes it as low GWP and zero ODP.

R-24 at 3.5 inches

R-7.5 at 1 inch and R-24 at 3.5 inches (ASTM C518), per the data sheet.

2-hour re-occupancy

Re-entry 1 hour and re-occupancy 2 hours with 10 air changes per hour (ASTM D8445).

Accufoam CC-HFO is an Accufoam product from Birmingham, Alabama, and we buy it through Pro Foam. The data sheet lists it for thermal insulation and as a vapor and air barrier.

Where we use it

Closed-cell foam goes on steel buildings, rim joists and crawl spaces, barndominiums and anywhere water contact is possible. The Department of Energy notes that closed-cell foam has a greater R-value and stronger resistance to moisture and air leakage than open-cell. For attic rooflines and interior walls we use open-cell, such as Accufoam AF1.

From the data sheet

PropertyValue on the data sheetTest method
R-value at 1 inch7.5ASTM C518
R-value at 3.5 inches24ASTM C518
Core density1.9 lb/ft³ASTM D1622
Open-cell contentless than 5%ASTM D6226
Surface burningFlame spread 25 or less, smoke developed 450 or less (Class 1)ASTM E84
Anti-fungalPassASTM C1338
Re-entry, with 10 air changes per hour1 hourASTM D8445
Re-occupancy, with 10 air changes per hour2 hoursASTM D8445
Maximum lift per pass3.5 inchesManufacturer application limit

Source: Accufoam CC-HFO Technical Data Sheet, revised 2025-06-05. The data sheet lists evaluation reports ER-833, ESR-5252 and ESL-1592.

Attics and crawl spaces

The data sheet states that it complies with the applicable requirements of AC377 Appendix X for use in attics and crawl spaces without a prescriptive ignition barrier. Whether that applies to your space depends on how the space is used and on the code, so ask us about yours.

Documents

These are the manufacturer's documents, hosted by our supplier. Ask us and we will give you the documents for your job.

Questions

Common questions

The data sheet lists R-7.5 at 1 inch and R-24 at 3.5 inches, tested to ASTM C518. Your scope states the applied depth.

The manufacturer lists it for thermal insulation and as a vapor and air barrier. The vapor rating depends on the applied depth, so ask us what your scope specifies.

The data sheet gives 1 hour for re-entry and 2 hours for re-occupancy with 10 air changes per hour of ventilation, tested to ASTM D8445. We confirm the time for your job before the day.

Next step

Ask which foam we would use in your building

The product, the applied depth and the price, in writing, before anything is ordered. Free to book.