Foam we spray

Accufoam AF1 Open-Cell Spray Foam

Accufoam AF1 is our main open-cell foam. It is what we spray on attic rooflines and interior walls in Houston houses. Every number on this page comes from the manufacturer's technical data sheet.

In short

Open-cell, water blown

A low-density, two-component spray foam. The data sheet says it is 100% water blown.

R-13 at 3.5 inches

R-3.7 at 1 inch and R-13 at 3.5 inches (ASTM C518), per the data sheet.

1-hour re-occupancy

With 10 air changes per hour of ventilation (ASTM D8445), per the data sheet.

Accufoam AF1 is made by Creative Polymer Solutions of Birmingham, Alabama, and we buy it through Pro Foam. The manufacturer describes it as a two-component, one-to-one by volume, spray-applied polyurethane foam for thermal insulation and air barrier assemblies.

Where we use it

Open-cell foam is what we use on attic rooflines and interior walls. For rim joists, crawl spaces, steel buildings and anywhere water contact is possible we use closed-cell foam, such as Accufoam CC-HFO. The Department of Energy notes that open-cell foam should not be used below ground level, where it could absorb water.

From the data sheet

PropertyValue on the data sheetTest method
R-value at 1 inch3.7ASTM C518
R-value at 3.5 inches13ASTM C518
Core density0.40 to 0.45 lb/ft³ASTM D1622
Open-cell contentmore than 90%ASTM D6226
Surface burningFlame spread under 25, smoke developed under 450 (Class 1)ASTM E84
Re-entry, with 10 air changes per hour1 hourASTM D8445
Re-occupancy, with 10 air changes per hour1 hourASTM D8445
Maximum lift per pass6 inchesManufacturer application limit
Unvented attic assemblies (roof deck)3 inches minimum, 18 inches maximumPer the data sheet, under evaluation CCRR-0487

Source: Accufoam AF1 Technical Data Sheet, revised 2024-07-10. The data sheet lists evaluation reports ER-842, ESR-5255 and CCRR-0487.

Documents

These are the manufacturer's documents, hosted by our supplier. Ask us and we will give you the documents for your job.

Fire safety

Spray foam is combustible. The data sheet lists the ignition barrier and thermal barrier coatings tested with this product, and the building code decides which one your space needs. Ask us which applies to yours.

Questions

Common questions

The data sheet lists R-3.7 at 1 inch and R-13 at 3.5 inches, tested to ASTM C518. Your scope states the applied depth, so you can work out what went in.

The data sheet gives a 1-hour re-entry and a 1-hour re-occupancy period with 10 air changes per hour of ventilation, tested to ASTM D8445. We confirm the time for your job before the day.

The manufacturer lists it for thermal insulation and air barrier assemblies. How well a whole house is sealed also depends on the rest of the assembly, which is why we look at the house first.

Next step

Ask which foam we would use in your building

The product, the applied depth and the price, in writing, before anything is ordered. Free to book.